Direct test of the three-phase asynchronous motor with electromagnetic (Pasqualini) brake |
Connection diagram:

The test points out the machine behaviour in the effective working conditions
and a mechanic load is therefore necessary to be applied to the motor under
test.
The mechanic load is made up, in the specific case, of the electromagnetic (Pasqualini)
brake allowing a gradual regulation of the braking effect, through the direct
current regulation flowing in its electromagnets.
The reference quantity is the couple and therefore the mechancal power at the
shaft, that generally is varied from 0 to 1.25 times the rated power.
|
|
The characteristic diagrams are: