DLHOME.GIF (1102 byte)

Gain  and  Offset  Adjust

DL 2683

Module DL 2683 allows the proportional adaptation  of the external signals to the normal voltages used in the automatic control systems.

Technical features

DL2683.gif (5474 byte)

Power supply: +15 V ; 0 V ; -15 V
Voltage interval of the input signal: -50 V, ..., +50 V
Adjustable level through the setting of the gain: 0 ....1, 0 .... 10, 0 .... 100
Attenuation of the pulse signals
Time constants  Equazione3.gif (279 byte)  :  0,1 .... 10 ms  ;  10 .... 100 ms
Offset voltages that can be connected:  -10 V .... +10 V
Coarse setting through rotary switches
Potentiometric fine setting

Description

1. Terminal for the input signal
2. Coarse and fine setting of the time constant
3. Coarse and fine setting of the gain
4. Setting of the offset
5. Switch for the selection of the offset insertion/exclusion
6. Terminal for the output signal