| A |
With switch 1 in position INT and switch 2 in position 0 / ±10 V,
terminal 4 provides voltage in the above mentioned range as a function of the position of
potentiometer 3. |
| B |
With switch 1 in position INT and switch 2 in position 0 / +10 V,
terminal 4 provides voltage in the above mentioned range as a function of the position of
potentiometer 3. |
| C |
With switch 1 in position EXT, terminal 4 provides the external reference
signal input to terminal 5. |
| D |
With terminal 6 connected to terminal 5 and switch 2 in position 0 / ±10
V, switching switch 1 from position EXT to position INT, terminal 4 provides steps of
negative or positive voltage as a function of the position of potentiometer 3. |
| E |
With terminal 6 connected to terminal 5 and switch 2 in position 0 / +10
V, switching switch 1 from position EXT to position INT, terminal 4 provides steps of
positive voltage as a function of the position of potentiometer 3. |
|
|
|
|